This procedure applies conditionally when a thorough examination or inspection of lifting equipment or an accessory identifies an unresolved defect that is or could become a danger to people.
Immediate withdrawal from use
When such a defect is identified, ensure that the affected lifting equipment or accessory, identified as [equipment or accessory id], is not used until the defect has been remedied.
Take effective action to prevent further use while the defect remains unresolved. The defect must be confirmed in writing in the examination or inspection report, even where it is remedied immediately.
Defects with a specified later deadline
If the report states that immediate cessation of use is not required but specifies a later remedy period, remedy the defect or stop further use within that period. Where a later deadline is specified, record it as [defect report deadline] and ensure that the required action is completed within the stated period.
Remedy and return to use
Do not permit the equipment or accessory to be used again while the dangerous or potentially dangerous defect remains unresolved. Return to use is permitted only after the defect has been remedied.
Where destruction is used as the remedy for an accessory, retain the disposal record and ensure that the written report confirms the defect and the action taken.
Report notification
The person making the examination or inspection report must notify the relevant enforcing authority and provide a copy of the report.
Sources
- Thorough examinations and inspections of lifting equipment - HSEHealth and Safety Executive (HSE)